CONDUCTIVE
NO WOVEN
»
Data Sheet |
|
|
 |
Conductive Non-Woven textile appears as compact felt, characterized by
a less volumetric resistivity, very good punching and competitive
price with respect to other materials, above all for medium/great (>5.000 pieces).
Such materials can be supply as semifinished in rolls or various height and
length spools for following customer machining or punching on drawing. |
|
Their use is recommended when it take a good Shielding Performance,
electrostatic discharges protections or grounding, without particular
environmental requirements.
Typical applications are: cable flanges, panel or plate connectors,
permanent closings on cabinets and easy to apply for shielding rooms.
|
|
UL
COMPLIANT |
RoHS
COMPLIANT |
|
PHYSICAL PROPERTIES |
NW.3 |
NW.4 |
NW.7 |
NW.10 |
|
CARRIER MATERIAL |
PET
100% |
PET
100% |
PET
100% |
PET
100% |
|
METAL |
Ni + Cu |
Ni + Cu |
Ni + Cu |
Ni + Cu |
|
COLOUR |
light grey |
grey |
light grey |
light grey |
|
THICKNESS |
0.3
mm |
0.4
mm |
0.7 mm |
1 mm |
|
WEIGHT |
150 g/mq |
235
g/mq |
385 g/mq |
535 g/mq |
|
AMOUNT OF METAL |
20 –
25 g/mq |
25 – 30
g/mq |
45
– 55 g/mq |
65
– 80 g/mq |
|
MAX SHORT DURATION TEMP. |
125°C |
125°C |
125°C |
125°C |
|
CONDUCTIVE ADHESIVE |
ONE
BOTH SIDE |
ONE
BOTH SIDE |
ONE
BOTH SIDE |
NO/ONE
BOTH SIDE |
|
MECHANICAL PROPRERTIES |
NW.3 |
NW.4 |
NW.7 |
NW.10 |
|
TENSILE STRENGTH
WARP-WEFT |
2-4
Kg/cm
±10% |
4-6
Kg/cm
±10% |
6-10
Kg/cm
±10% |
9-13
Kg/cm
±10% |
|
ELONGATION
WARP-WEFT |
3-4% |
3-4% |
2-3% |
1-2% |
|
ELECTRICAL PROPERTIES |
NW.3 |
NW.4 |
NW.7 |
NW.10 |
|
SURFACE RESISTIVITY |
< 0,09
Ω/sq |
< 0,08
Ω/sq |
< 0,07
Ω/sq |
< 0,06
Ω/sq |
|
SHIELDING PERFORMANCE @ 1GH |
>
60dB |
>
70dB |
>
80dB |
> 90dB |
|
EMI SHIELDING PERFORMANCES / MIL-STD-285 |
|
 |
 |
|
|